Full proposal
Full removal of combustible components within all three external wall types, including PIR/PUR rigid foam insulation, timber cladding, and EPS insulation associated with the render system. Replacement with a compliant system using materials achieving European Classification A2-s1,d0 (limited combustibility) or Class A1 (non-combustible). Installation of cavity barriers and fire-stopping measures at all compartment floors and walls, around windows, doors, and service penetrations to restore compartmentation. Retention of suitable components such as terracotta tiles and aluminium support structures. Reinstatement of external finishes on a like-for-like basis, replicating the existing appearance, colour, and texture.